Description
The display can be selected to show flow rate
resettable total weight or non-resettable total weight from the front
panel keys. Settings and calibration data can be accessed with a pass
number. In application where the belt speed variations are insignificant,
the controller can operate with out the tachometer pulse signal.
Dynamic Tare
Once started by simple push button operation when the
belt is running empty, the system automatically totalizes the weight both
+ve and –ve. Over a number of belt movements pulses. When complete it
adjusts the weigher is entered.
Dynamic Calibration Check & Recalibration
Once similarly started by a push button operation, a
known weight is passed over the weigher, totalizing is stopped and the
total is observed to make the calibration check. To make a recalibration
the known weight is entered.